Q:

Following three questions refer to the information below. A coal-fired power plant produces and sells 10,000 MW electricity while operating at 40% thermal efficiency. The sale prioe of electric power is $0.04 per kWh. How much power does it reject to the atmosphere? How much power (in the form of heat rate) does it require from coal combustion?

Accepted Solution

A:
Answer: Heat rejected=150000MWHeat rate= 2.5Step-by-step explanation:Thermal efficiency is defined as work out divided by heat in.Thereforethermal efficiency = 40/100= 100000 MW/Heat inHeat in = 250000MWFor a closed system undergoing a cycle the change in internal energy is zero. Therefore the work out of the system is equal to the net heat transfer of the system. ThereforeWork out= heat in - heat outTherefore heat out = heat in - work outHeat out = 250000 MW - 100000MW = 150000 MW which is the amount of heat rejectedThe heat rate is defined as the inverse of the thermal efficiency expressed in kJ/kWh.Therefore Heat rate = 1/thermal efficiency Heat rate = 1/0.4 = 2.5 kJ/kWh